A rapid method for simultaneous determination of arsenic, cadmium and lead in drinking water by inductively coupled plasma mass spectrometry / (Record no. 87018)

MARC details
000 -LEADER
fixed length control field 02152nam a2200253Ia 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 241022s2010 xx 000 0 und d
040 ## - CATALOGING SOURCE
Transcribing agency
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Torres, Joshua Rey P.
9 (RLIN) 14777
245 #2 - TITLE STATEMENT
Title A rapid method for simultaneous determination of arsenic, cadmium and lead in drinking water by inductively coupled plasma mass spectrometry /
Statement of responsibility, etc. Joshua Rey P. Torres, Ma. Krystell G. Banaag, Irene B. Rodriguez
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc. 2010
336 ## - CONTENT TYPE
Content type term text
337 ## - MEDIA TYPE
Media type term unmediated
338 ## - CARRIER TYPE
Carrier type term volume
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE
Number of part/section of a work 22 : 1, pages 1-8
Title Science Diliman
9 (RLIN) 14778
520 ## - SUMMARY, ETC.
Summary, etc. The raw water source of drinking water in most areas in the Philippines is typically river water and in some cases groundwater. These sources are prone to elevated levels of metals and metalloids that may cause exposure of the general population when the treatment of the water is inadequate. This work presents a simple method based on EPA Method 200.8 for the determination of total concentrations of arsenic (As), cadmium (Cd) and lead (Pb) in drinking water using inductively coupled plasma-mass spectrometry (ICP-MS) as the element-selective detector. This was applied in the determination of these elements in the water supply in Metro Manila, Philippines. The method detection limits were 0.095mgL-1, 0.043mgL-1, and 0.114mgL-1 for total As, Cd and Pb, respectively. The method was validated using National Institute of Standards and Technology (NIST) 1643e certified reference material for trace elements in water and determined values were 60.4+-0.5mgL-1, and 19.6+-0.5mgL-1 for As, Cd and Pb, respectively. These determined values were in good agreement with the certified values in the reference material. Analysis of actual drinking water samples showed that most samples did not exceed the limit of the Philippine drinking water standard for the elements.
521 ## - TARGET AUDIENCE NOTE
Target audience note General Education.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Arsenic.
9 (RLIN) 14779
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Cadmium.
9 (RLIN) 14780
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Drinking water.
9 (RLIN) 6513
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Inductively coupled plasma-mass spectrometry (ICP-MS).
9 (RLIN) 14781
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Lead.
9 (RLIN) 14782
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Metro Manila.
9 (RLIN) 14783
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Articles
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Date last seen Price effective from Koha item type
    Library of Congress Classification     Manila Tytana Colleges Library Manila Tytana Colleges Library REFERENCE SECTION 10/22/2024   10/22/2024 10/22/2024 Articles
Manila Tytana Colleges Library | Metropolitan Park, Pres. Diosdado Macapagal Blvd., Pasay City, 1300
Tel.(+63-2) 859-0826 | E-mail library@mtc.edu.ph