Content validity testing of the maternal fetal triage index / (Record no. 77431)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02222nab a22002777a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | PILC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20221123182303.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 150723s9999 xx 000 0 und d |
040 ## - CATALOGING SOURCE | |
Transcribing agency | MANILA TYTANA COLLEGES LIBRARY |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ruhl, Catherine. |
245 0# - TITLE STATEMENT | |
Title | Content validity testing of the maternal fetal triage index / |
Statement of responsibility, etc. | Catherine Ruhl, Benjamin Scheich, Brea Onokpise, Debra Bingham |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc. | November-December 2015. |
336 ## - CONTENT TYPE | |
Content type term | text |
337 ## - MEDIA TYPE | |
Media type term | unmediated |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE | |
Title | Journal of Obstetric, Gynecologic & Neonatal Nursing |
Number of part/section of a work | 44 : 6, page 701-709 |
520 ## - SUMMARY, ETC. | |
Summary, etc. | "Objective To describe the development and content validity testing of the Maternal Fetal Triage Index (MFTI), a standardized tool for obstetric triage. Design Online survey. Participants Participants included 15 registered nurses, 15 certified nurse-midwives, and 15 physicians from across the United States who provided maternity care. Methods A convenience sample of experienced clinicians was used as content validators for the MFTI. An item content validity index (I-CVI) was computed for the tool's items and a scale content validity index (S-CVI) was computed for the tool's scale based on the responses submitted via the online survey. Two rounds of content validation occurred. Results In the first round of testing, a total of 12 of 61 items in the MFTI did not meet the I-CVI threshold of greater than 0.78 because of disagreement about clinical condition (75%) or priority level placement (25%). In the second round of testing, all but 3 of the 69 content items in the revised version of the MFTI had I-CVI thresholds greater than 0.78. These 3 items were related to vital sign values. The overall S-CVI score calculated for Round 2 only was 0.95, whichwas greater than the threshold of 0.90. Conclusion The results of the content validity testing of multidisciplinary validators suggest that the MFTI is a valid tool for use in obstetric triage and evaluation settings." |
521 ## - TARGET AUDIENCE NOTE | |
Target audience note | Nursing |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Obstetrics. |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Triage (Medicine). |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Scheich, Benjamin. |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Onokpise, Brea. |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Bingham, Debra. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | Articles |
Source of classification or shelving scheme | Library of Congress Classification |
998 ## - LOCAL CONTROL INFORMATION (RLIN) | |
Cataloger's initials, CIN (RLIN) | 80430 |
First Date, FD (RLIN) | 138793 |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Library of Congress Classification | Not For Loan | Manila Tytana Colleges Library | Manila Tytana Colleges Library | REFERENCE SECTION | 09/11/2017 | Bound | 09/11/2017 | 09/11/2017 | Articles |