Content validity testing of the maternal fetal triage index / (Record no. 77431)

MARC details
000 -LEADER
fixed length control field 02222nab a22002777a 4500
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20221123182303.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150723s9999 xx 000 0 und d
040 ## - CATALOGING SOURCE
Transcribing agency MANILA TYTANA COLLEGES LIBRARY
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Ruhl, Catherine.
245 0# - TITLE STATEMENT
Title Content validity testing of the maternal fetal triage index /
Statement of responsibility, etc. Catherine Ruhl, Benjamin Scheich, Brea Onokpise, Debra Bingham
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc. November-December 2015.
336 ## - CONTENT TYPE
Content type term text
337 ## - MEDIA TYPE
Media type term unmediated
338 ## - CARRIER TYPE
Carrier type term volume
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE
Title Journal of Obstetric, Gynecologic & Neonatal Nursing
Number of part/section of a work 44 : 6, page 701-709
520 ## - SUMMARY, ETC.
Summary, etc. "Objective To describe the development and content validity testing of the Maternal Fetal Triage Index (MFTI), a standardized tool for obstetric triage. Design Online survey. Participants Participants included 15 registered nurses, 15 certified nurse-midwives, and 15 physicians from across the United States who provided maternity care. Methods A convenience sample of experienced clinicians was used as content validators for the MFTI. An item content validity index (I-CVI) was computed for the tool's items and a scale content validity index (S-CVI) was computed for the tool's scale based on the responses submitted via the online survey. Two rounds of content validation occurred. Results In the first round of testing, a total of 12 of 61 items in the MFTI did not meet the I-CVI threshold of greater than 0.78 because of disagreement about clinical condition (75%) or priority level placement (25%). In the second round of testing, all but 3 of the 69 content items in the revised version of the MFTI had I-CVI thresholds greater than 0.78. These 3 items were related to vital sign values. The overall S-CVI score calculated for Round 2 only was 0.95, whichwas greater than the threshold of 0.90. Conclusion The results of the content validity testing of multidisciplinary validators suggest that the MFTI is a valid tool for use in obstetric triage and evaluation settings."
521 ## - TARGET AUDIENCE NOTE
Target audience note Nursing
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Obstetrics.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Triage (Medicine).
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Scheich, Benjamin.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Onokpise, Brea.
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Bingham, Debra.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Articles
Source of classification or shelving scheme Library of Congress Classification
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Cataloger's initials, CIN (RLIN) 80430
First Date, FD (RLIN) 138793
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Date last seen Price effective from Koha item type
    Library of Congress Classification   Not For Loan Manila Tytana Colleges Library Manila Tytana Colleges Library REFERENCE SECTION 09/11/2017   Bound 09/11/2017 09/11/2017 Articles
Manila Tytana Colleges Library | Metropolitan Park, Pres. Diosdado Macapagal Blvd., Pasay City, 1300
Tel.(+63-2) 859-0826 | E-mail library@mtc.edu.ph