Milk flow rates from bottle nipples used after hospital discharge / (Record no. 76285)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02212nab a22002417a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | PILC |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20221123182229.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 150723s9999 xx 000 0 und d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | 0361-929X |
040 ## - CATALOGING SOURCE | |
Transcribing agency | MANILA TYTANA COLLEGES LIBRARY |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Pados, Britt Frisk |
245 #0 - TITLE STATEMENT | |
Title | Milk flow rates from bottle nipples used after hospital discharge / |
Statement of responsibility, etc. | Britt Frisk Pados, Jinhee Park, Suzanne M. Thoyre, Hayley Estrem, W. Brant Nix |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc. | July/August 2016. |
336 ## - CONTENT TYPE | |
Content type term | text |
337 ## - MEDIA TYPE | |
Media type term | unmediated |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE | |
Title | MCN : The American Journal of Maternal/Child Nursing |
Number of part/section of a work | 41 : 4 page 237-243 |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Purpose: To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Study Design and Methods: Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R' Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n = 260 total) were tested by measuring the amount of infant formula expressed in 1 minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Results: Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown's Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown's Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. Clinical Implications: The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice. |
521 ## - TARGET AUDIENCE NOTE | |
Target audience note | Nursing |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Bottle feeding. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | Articles |
Source of classification or shelving scheme | Library of Congress Classification |
998 ## - LOCAL CONTROL INFORMATION (RLIN) | |
Cataloger's initials, CIN (RLIN) | 79267 |
First Date, FD (RLIN) | 137630 |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Library of Congress Classification | Not For Loan | Manila Tytana Colleges Library | Manila Tytana Colleges Library | REFERENCE SECTION | 02/07/2017 | Bound | 02/07/2017 | 02/07/2017 | Articles |