Milk flow rates from bottle nipples used after hospital discharge / (Record no. 76285)

MARC details
000 -LEADER
fixed length control field 02212nab a22002417a 4500
003 - CONTROL NUMBER IDENTIFIER
control field PILC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20221123182229.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150723s9999 xx 000 0 und d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0361-929X
040 ## - CATALOGING SOURCE
Transcribing agency MANILA TYTANA COLLEGES LIBRARY
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Pados, Britt Frisk
245 #0 - TITLE STATEMENT
Title Milk flow rates from bottle nipples used after hospital discharge /
Statement of responsibility, etc. Britt Frisk Pados, Jinhee Park, Suzanne M. Thoyre, Hayley Estrem, W. Brant Nix
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc. July/August 2016.
336 ## - CONTENT TYPE
Content type term text
337 ## - MEDIA TYPE
Media type term unmediated
338 ## - CARRIER TYPE
Carrier type term volume
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE
Title MCN : The American Journal of Maternal/Child Nursing
Number of part/section of a work 41 : 4 page 237-243
520 ## - SUMMARY, ETC.
Summary, etc. Purpose: To test the milk flow rates and variability in flow rates of bottle nipples used after hospital discharge. Study Design and Methods: Twenty-six nipple types that represented 15 common brands as well as variety in price per nipple and store location sold (e.g., Babies R' Us, Walmart, Dollar Store) were chosen for testing. Ten of each nipple type (n = 260 total) were tested by measuring the amount of infant formula expressed in 1 minute using a breast pump. Mean milk flow rate (mL/min) and coefficient of variation (CV) were calculated. Flow rates of nipples within brand were compared statistically. Results: Milk flow rates varied from 1.68 mL/min for the Avent Natural Newborn Flow to 85.34 mL/min for the Dr. Brown's Standard Y-cut. Variability between nipple types also varied widely, from .03 for the Dr. Brown's Standard Level 3 to .37 for MAM Nipple 1 Slow Flow. Clinical Implications: The extreme range of milk flow rates found may be significant for medically fragile infants being discharged home who are continuing to develop oral feeding skills. The name of the nipple does not provide clear information about the flow rate to guide parents in decision making. Variability in flow rates within nipples of the same type may complicate oral feeding for the medically fragile infant who may not be able to adapt easily to change in flow rates. Both flow rate and variability should be considered when guiding parents to a nipple choice.
521 ## - TARGET AUDIENCE NOTE
Target audience note Nursing
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Bottle feeding.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Articles
Source of classification or shelving scheme Library of Congress Classification
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Cataloger's initials, CIN (RLIN) 79267
First Date, FD (RLIN) 137630
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Date last seen Price effective from Koha item type
    Library of Congress Classification   Not For Loan Manila Tytana Colleges Library Manila Tytana Colleges Library REFERENCE SECTION 02/07/2017   Bound 02/07/2017 02/07/2017 Articles
Manila Tytana Colleges Library | Metropolitan Park, Pres. Diosdado Macapagal Blvd., Pasay City, 1300
Tel.(+63-2) 859-0826 | E-mail library@mtc.edu.ph