TY - BOOK AU - Torres, Joshua Rey P. TI - A rapid method for simultaneous determination of arsenic, cadmium and lead in drinking water by inductively coupled plasma mass spectrometry / PY - 2010/// KW - Arsenic KW - Cadmium KW - Drinking water KW - Inductively coupled plasma-mass spectrometry (ICP-MS) KW - Lead KW - Metro Manila N1 - General Education N2 - The raw water source of drinking water in most areas in the Philippines is typically river water and in some cases groundwater. These sources are prone to elevated levels of metals and metalloids that may cause exposure of the general population when the treatment of the water is inadequate. This work presents a simple method based on EPA Method 200.8 for the determination of total concentrations of arsenic (As), cadmium (Cd) and lead (Pb) in drinking water using inductively coupled plasma-mass spectrometry (ICP-MS) as the element-selective detector. This was applied in the determination of these elements in the water supply in Metro Manila, Philippines. The method detection limits were 0.095mgL-1, 0.043mgL-1, and 0.114mgL-1 for total As, Cd and Pb, respectively. The method was validated using National Institute of Standards and Technology (NIST) 1643e certified reference material for trace elements in water and determined values were 60.4+-0.5mgL-1, and 19.6+-0.5mgL-1 for As, Cd and Pb, respectively. These determined values were in good agreement with the certified values in the reference material. Analysis of actual drinking water samples showed that most samples did not exceed the limit of the Philippine drinking water standard for the elements ER -